Model
|
Normal
capacity
|
Absorbed
power
|
Air
connections
|
Dimensions
L x W x H
|
Weights
|
Condensate
flow
|
|
(1)
scfm
|
(2)
kW
|
NPT
|
inches
|
(3)
lb
|
lb/h
|
| CTD15 |
18
|
0.25
|
1/2"
|
18.3x16.3x21.7
|
108
|
0.38
|
|
CTD25
|
30
|
0.39
|
1/2"
|
18.3x16.3x21.7
|
121
|
0.63
|
| CTD35 |
35
|
0.29
|
3/4"
|
23x19.3x26.4
|
176
|
0.74
|
| CTD50 |
50
|
0.42
|
3/4"
|
23x19.3x26.4
|
176
|
1.05
|
| CTD75 |
75
|
0.59
|
3/4"
|
23x19.3x26.4
|
203
|
1.58
|
| CTD100 |
100
|
0.79
|
3/4"
|
23x19.3x26.4
|
203
|
2.09
|
| CTD125 |
120
|
0.79
|
1"
|
29.3x21.7x36.5
|
278
|
2.54
|
| CTD150 |
150
|
1.03
|
1"
|
29.3x21.7x36.5
|
337
|
3.15
|
| CTD175 |
180
|
1.24
|
1"
|
29.3x21.7x36.5
|
337
|
3.80
|
| CTD200 |
200
|
1.02
|
1
1/2"
|
29.3x27.6x38
|
388
|
4.20
|
| CTD250 |
250
|
1.27
|
1
1/2"
|
29.3x27.6x38
|
388
|
5.25
|
| CTD300 |
321
|
1.84
|
1
1/2"
|
29.3x27.6x38
|
483
|
6.74
|
| CTD350 |
350
|
1.68
|
2"
|
29.3x40.2x46.7
|
706
|
7.35
|
| CTD400 |
420
|
2.01
|
2"
|
29.3x40.2x46.7
|
706
|
8.82
|
| CTD450 |
450
|
2.56
|
2"
|
29.3x40.2x46.7
|
758
|
9.45
|
| CTD500 |
516
|
2.94
|
2"
|
29.3x40.2x46.7
|
758
|
10.8
|
| CTD600 |
650
|
2.85
|
3"
|
33.9x51.2x81.7
|
1378
|
13.7
|
| CTD700 |
700
|
3.18
|
3"
|
33.9x51.2x81.7
|
1389
|
14.7
|
| CTD800 |
800
|
3.63
|
3"
|
33.9x51.2x81.7
|
1389
|
16.8
|
| CTD1000 |
1000
|
4.88
|
3"
|
33.9x51.2x81.7
|
1384
|
21.0
|
| CTD1200 |
1200
|
5.85
|
3"
|
33.9x51.2x81.7
|
1384
|
25.2
|
| CTD1600 |
1600
|
7.17
|
4"
|
33.9x51.2x81.7
|
2513
|
33.6
|
| CTD2000 |
1900
|
9.3
|
4"
|
33.9x51.2x81.7
|
3064
|
39.9
|
|
Model
|
Air
pressure
drop (1)
|
Electrical
supply
|
Max.
current*
|
Fan
current
|
Fan
power
|
Compress.
current
|
LCR
Fuse
TRM(a)-ATQ(b)
|
Heat
rejection
|
|
psi
|
V/ph/Hz
|
Amps
|
Amps
|
kW
|
Amps
|
|
kW
|
| CTD15 |
3.99
|
115±5%/1/60
|
4.3
|
0.7
|
0.054
|
3.63
|
12
(a)
|
0.74
|
|
CTD25
|
3.95
|
115±5%/1/60
|
5.5
|
0.7
|
0.054
|
4.81
|
12
(a)
|
1.2
|
| CTD35 |
2.05
|
115±5%/1/60
|
6.4
|
1.6
|
0.12
|
4.81
|
12
(a)
|
1.11
|
| CTD50 |
4.18
|
115±5%/1/60
|
6.4
|
1.6
|
0.12
|
4.81
|
12
(a)
|
1.11
|
| CTD75 |
2.55
|
115±5%/1/60
|
12.0
|
1.6
|
0.12
|
10.2
|
15
(a)
|
2.45
|
| CTD100 |
4.54
|
115±5%/1/60
|
12.0
|
1.6
|
0.12
|
10.2
|
15
(a)
|
2.45
|
| CTD125 |
4.14
|
230±5%/1/60
|
6.4
|
0.78
|
0.11
|
5.6
|
15
(a)
|
2.43
|
| CTD150 |
2.93
|
230±5%/1/60
|
8.5
|
0.48
|
0.11
|
8
|
15
(a)
|
4.08
|
| CTD175 |
4.22
|
230±5%/1/60
|
8.5
|
0.48
|
0.11
|
8
|
15
(a)
|
4.08
|
| CTD200 |
2.84
|
230±5%/1/60
|
9.3
|
0.93
|
0.2
|
8.4
|
20
(a)
|
4.7
|
| CTD250 |
4.44
|
230±5%/1/60
|
9.3
|
0.93
|
0.2
|
8.4
|
20
(a)
|
4.7
|
| CTD300 |
4.57
|
230±5%/1/60
|
12.6
|
1.3
|
0.3
|
11.3
|
20
(a)
|
6.16
|
| CTD350 |
3.19
|
460±5%/3/60
|
5.4
|
0.71
|
0.44
|
4.5
|
12
(b)
|
7.11
|
| CTD400 |
4.59
|
460±5%/3/60
|
5.4
|
0.71
|
0.44
|
4.5
|
12
(b)
|
7.11
|
| CTD450 |
3.40
|
460±5%/3/60
|
6.1
|
0.71
|
0.44
|
5.2
|
15
(b)
|
9.52
|
| CTD500 |
4.47
|
460±5%/3/60
|
6.1
|
0.71
|
0.44
|
5.2
|
15
(b)
|
9.52
|
| CTD600 |
2.67
|
460±5%/3/60
|
6.5
|
1.1
|
0.7
|
5.2
|
20
(b)
|
10.49
|
| CTD700 |
3.00
|
460±5%/3/60
|
8.3
|
1.1
|
0.7
|
7
|
20
(b)
|
13.05
|
| CTD800 |
3.92
|
460±5%/3/60
|
8.3
|
1.1
|
0.7
|
7
|
20
(b)
|
13.05
|
| CTD1000 |
2.72
|
460±5%/3/60
|
13.3
|
1.1
|
0.7
|
12
|
20
(b)
|
19.92
|
| CTD1200 |
3.92
|
460±5%/3/60
|
13.3
|
1.1
|
0.7
|
12
|
20
(b)
|
19.92
|
| CTD1600 |
3.92
|
460±5%/3/60
|
14.8
|
2x1.1
|
2x0.7
|
12.3
|
30
(b)
|
25.98
|
| CTD2000 |
3.57
|
460±5%/3/60
|
20.0
|
2x1.1
|
2x0.7
|
17.5
|
30
(b)
|
31.31
|
*Max
current at operational limit conditions
(1) Capacities to ANSI/CAGI ADF 100-1998: 100°F inlet temperature,
100 psig inlet pressure, 100°F ambient temperature, to deliver 33°F
to 39°F pressure dew point
(2) Absorbed power at nominal working conditions
(3) Shipping weights
(4) Hermetically sealed refrigerant compressors used with R134a gas
(5) Standard units suitable for working pressure up to 230 psig and
optional versions are available up to 725 psig
(6) Minimum and maximum ambient temperature 41°F and 110°F
(7) Maximum compressed air inlet temperature 140°F
All models IP22 insulation class
All models free-field sound pressure level < 70dBA
Installation
CTD dryers must be sited on level ground in an indoor frost-free location.
Adequate ventilation and maintenance access must be provided. The dryer
should normally be connected after the receiver with appropriate CompAir
filter protection.