Cycling vs. Non-Cycling Dryers
CompAir features a unique, patented heat exchanger located inside a dry non-toxic Cold Energy Block. This innovative design offers electrical energy

savings of 30 to 80% compared to traditional non-cycling refrigeration dryers. Because cycling dryers are able to adjust their capacity to match the actual compressed air load profile, they are able to provide dramatic savings in power consumption, when compared to non-cycling dryers, during times when the demand or ambient conditions result in a load less than design.

The graph shown illustrates the yearly power costs of 12oo cfm cycling and non-cycling dryers. The

cycling effect of the CTD1200 is shown on the bottom two lines. Cycling saves energy both in response to reduced compressed air flow rate (cfm) as well as to reduced compressed air inlet temperature.
The upper line represents the constant cost associated with a non-cycling dryer (which can only adjust to load variations by false loading of the evaporator using a hot gas bypass valve) that consumes full power regardless of load.
 
 
Model

Normal
capacity

Absorbed
power
Air
connections
Dimensions
L x W x H
Weights
Condensate
flow
(1) scfm
(2) kW
NPT
inches
(3) lb
lb/h
CTD15
18
0.25
1/2"
18.3x16.3x21.7
108
0.38

CTD25

30
0.39
1/2"
18.3x16.3x21.7
121
0.63
CTD35
35
0.29
3/4"
23x19.3x26.4
176
0.74
CTD50
50
0.42
3/4"
23x19.3x26.4
176
1.05
CTD75
75
0.59
3/4"
23x19.3x26.4
203
1.58
CTD100
100
0.79
3/4"
23x19.3x26.4
203
2.09
CTD125
120
0.79
1"
29.3x21.7x36.5
278
2.54
CTD150
150
1.03
1"
29.3x21.7x36.5
337
3.15
CTD175
180
1.24
1"
29.3x21.7x36.5
337
3.80
CTD200
200
1.02
1 1/2"
29.3x27.6x38
388
4.20
CTD250
250
1.27
1 1/2"
29.3x27.6x38
388
5.25
CTD300
321
1.84
1 1/2"
29.3x27.6x38
483
6.74
CTD350
350
1.68
2"
29.3x40.2x46.7
706
7.35
CTD400
420
2.01
2"
29.3x40.2x46.7
706
8.82
CTD450
450
2.56
2"
29.3x40.2x46.7
758
9.45
CTD500
516
2.94
2"
29.3x40.2x46.7
758
10.8
CTD600
650
2.85
3"
33.9x51.2x81.7
1378
13.7
CTD700
700
3.18
3"
33.9x51.2x81.7
1389
14.7
CTD800
800
3.63
3"
33.9x51.2x81.7
1389
16.8
CTD1000
1000
4.88
3"
33.9x51.2x81.7
1384
21.0
CTD1200
1200
5.85
3"
33.9x51.2x81.7
1384
25.2
CTD1600
1600
7.17
4"
33.9x51.2x81.7
2513
33.6
CTD2000
1900
9.3
4"
33.9x51.2x81.7
3064
39.9

 

Model

Air
pressure
drop (1)

Electrical
supply
Max.
current*
Fan
current
Fan
power
Compress.
current
LCR Fuse
TRM(a)-ATQ(b)
Heat
rejection
psi
V/ph/Hz
Amps
Amps
kW
Amps
kW
CTD15
3.99
115±5%/1/60
4.3
0.7
0.054
3.63
12 (a)
0.74

CTD25

3.95
115±5%/1/60
5.5
0.7
0.054
4.81
12 (a)
1.2
CTD35
2.05
115±5%/1/60
6.4
1.6
0.12
4.81
12 (a)
1.11
CTD50
4.18
115±5%/1/60
6.4
1.6
0.12
4.81
12 (a)
1.11
CTD75
2.55
115±5%/1/60
12.0
1.6
0.12
10.2
15 (a)
2.45
CTD100
4.54
115±5%/1/60
12.0
1.6
0.12
10.2
15 (a)
2.45
CTD125
4.14
230±5%/1/60
6.4
0.78
0.11
5.6
15 (a)
2.43
CTD150
2.93
230±5%/1/60
8.5
0.48
0.11
8
15 (a)
4.08
CTD175
4.22
230±5%/1/60
8.5
0.48
0.11
8
15 (a)
4.08
CTD200
2.84
230±5%/1/60
9.3
0.93
0.2
8.4
20 (a)
4.7
CTD250
4.44
230±5%/1/60
9.3
0.93
0.2
8.4
20 (a)
4.7
CTD300
4.57
230±5%/1/60
12.6
1.3
0.3
11.3
20 (a)
6.16
CTD350
3.19
460±5%/3/60
5.4
0.71
0.44
4.5
12 (b)
7.11
CTD400
4.59
460±5%/3/60
5.4
0.71
0.44
4.5
12 (b)
7.11
CTD450
3.40
460±5%/3/60
6.1
0.71
0.44
5.2
15 (b)
9.52
CTD500
4.47
460±5%/3/60
6.1
0.71
0.44
5.2
15 (b)
9.52
CTD600
2.67
460±5%/3/60
6.5
1.1
0.7
5.2
20 (b)
10.49
CTD700
3.00
460±5%/3/60
8.3
1.1
0.7
7
20 (b)
13.05
CTD800
3.92
460±5%/3/60
8.3
1.1
0.7
7
20 (b)
13.05
CTD1000
2.72
460±5%/3/60
13.3
1.1
0.7
12
20 (b)
19.92
CTD1200
3.92
460±5%/3/60
13.3
1.1
0.7
12
20 (b)
19.92
CTD1600
3.92
460±5%/3/60
14.8
2x1.1
2x0.7
12.3
30 (b)
25.98
CTD2000
3.57
460±5%/3/60
20.0
2x1.1
2x0.7
17.5
30 (b)
31.31

*Max current at operational limit conditions
(1) Capacities to ANSI/CAGI ADF 100-1998: 100°F inlet temperature, 100 psig inlet pressure, 100°F ambient temperature, to deliver 33°F to 39°F pressure dew point
(2) Absorbed power at nominal working conditions
(3) Shipping weights
(4) Hermetically sealed refrigerant compressors used with R134a gas
(5) Standard units suitable for working pressure up to 230 psig and optional versions are available up to 725 psig
(6) Minimum and maximum ambient temperature 41°F and 110°F
(7) Maximum compressed air inlet temperature 140°F
All models IP22 insulation class
All models free-field sound pressure level < 70dBA

Installation
CTD dryers must be sited on level ground in an indoor frost-free location. Adequate ventilation and maintenance access must be provided. The dryer should normally be connected after the receiver with appropriate CompAir filter protection.

 

 
 
 
 